MSL INTERNATIONAL
Schalungssysteme Lufttechnik Produktinfos News Über uns Kontakt
Construction Joint Systems | Foundation Tube Systems | Pipe Systems | Foundation Formwork Systems
 
 

MODELS

CORRUGATED PROFILE

STANDARD

ROUND CAVITY

ROUND CAVITY WITH ADDITIONAL REINFORCEMENT AND INTERLOCKING JOINTS

CONICAL DESIGN

FOLDING TUBING SHUTTERING
TYPE FKF EASY

FOLDING TUBING SHUTTERING
TYPE FKF

CAVITY MAKERS, SQUARE

MACHINE FOUNDATIONS

TAILORED SHUTTERING

TRAPEZOIDAL PROFILE

FOUNDATION TUBES WITH TRAPEZOIDAL PROFILE

SPHERICAL SHELL TUBING

BLOCK FOUNDATIONS

FOLDED SPIRAL-SEAM PIPING

FOUNDATION PIPING

BEADED CAVITY PIPING


ACCESSOIRES

CONTINUOUSLY HEIGHT ADJUSTABLE

REUSABLE CONTINUOUSLY ADJUSTABLE REINFORCING

BASE PLATES, COVER, ANCHOR BARS, REINFORCING, AIDS EASING ASSEMBLY

 
     
   
 

Folded spiral-seam piping of zinc-coated sheet metal
type FKVR

 
         
 

Lammpost foundations

The problem:

Damaged lampposts or signs directly
concreted into the ground have to be
expensively dug out.

The solution:

Photo 1:
The cavities are inserted in the ground, wiring installed and they are then filled with concrete from outside.
Photo 2:
The post is then fixed in place and the cavity filled with sand.
Photos 3 and 4:
Finally, a thin coat of lean concrete is poured at the top that can easily be removed in the event of damage.

 

 

Folded spiral-seam piping of zinc-coated sheet metal:

  • ready for installation
  • with / without inserted base plate / top cover
  • with / without cut-outs or drill holes for wiring

System descriptions:

MSL foundation piping is manufactured using the same process as for displacement piping - screw-shaped bend, folded leak proof. Reinforcement beading of 2.5 to 9 mmdepending on diameter gives the foundation piping very high strength to resist the pressure of the fresh concrete. The piping can be made in any desired length. It can be supplied with base plate rolled in if the intended use dictates. Loose top covers are offered. Please note these cannot be stepped on in the stan-dard design. Piping is available in diameters from 4 to 200 cm.

When used as lamppost foundations cut-outs or drill holes for later wiring can be provided. MSL foundation piping type FKVR is usually supplied zinc coated. It is used e.g. as external
shuttering for block foundations, as foundation shuttering for posts and signs, as electricity pylon foundations or as shuttering elements for lamp post foundations. In the event of damage it makes it easier and cheaper to replace a lamppost.

Brochure: Foundation tube systems
System Specifications type FKVR, offer text and customer inquiry

Example of use:
Electricity pylon foundations, photos 5 to 10

 
         
   
 
::: HOME ::: TOP ::: LINKS ::: GENERAL TERMS & CONDITIONS ::: IMPRINT :::

MSL - your specialist for temporary shuttering, shuttering systems, shuttering technology,
foundation shuttering, construction products

Copyright © 2007 MSL GmbH - Mathieu Schalungssysteme u. Lufttechnische Komponenten GmbH